Search Result
Search Result
-
250SF/250SFK 500SF/500SFK
Details- Series
- Compact fast acting fuses
- Rated
Current - 250SF/SFK: 10~25A
500SF/SFK: 10~20A - Cylinder size
(Estimated) - φ6.4×31
- Installation
method - Clipped / Board soldered
- Standard
approved -
- Rated Voltage
- 250SF/SFK: 250V
500SF/SFK: 500V
Application
-
500VSK/500VSH/400VSK
Details- Series
- Compact fast acting fuses
- Rated
Current - 10~60A
- Cylinder size
(Estimated) - φ6.6×24.6
- Installation
method - Screwed / Board Soldered
- Standard
approved -
- Rated Voltage
- 450V/400V
Application
-
400KH/400KHK
Details- Series
- Compact fast acting fuses
- Rated
Current - 5~60A
- Cylinder size
(Estimated) - φ11×26
- Installation
method - Screwed / Board soldered
- Standard
approved -
- Rated Voltage
- 400V
Application
-
660CF/KH/KHK
Details- Series
- Compact fast acting fuses
- Rated
Current - 5~60A
- Cylinder size
(Estimated) - φ10×38
- Installation
method - Clipped/ Screwed/ Board soldered
- Standard
approved -
- Rated Voltage
- 660V
Application
-
350GHK
Details- Series
- Cylindrical fast acting fuses
- Rated
Current - 50~100A
- Cylinder size
(Estimated) - φ17×22
- Installation
method - Board soldered
- Standard
approved -
- Rated Voltage
- 380Ⅴ
Application
-
750GH
Details- Series
- Cylindrical fast acting fuses
- Rated
Current - 20~710A
- Cylinder size
(Estimated) - φ17×46~
- Installation
method - Screwed
- Standard
approved -
- Rated Voltage
- 850V
Application
-
750GHK
Details- Series
- Cylindrical fast acting fuses
- Rated
Current - 50~100A
- Cylinder size
(Estimated) - φ17×44
- Installation
method - Board soldered
- Standard
approved -
- Rated Voltage
- 850V
Application
-
1000VGH
Details- Series
- Cylindrical fast acting fuses
- Rated
Current - 16~500A
- Cylinder size
(Estimated) - φ18×66~
- Installation
method - Screwed
- Standard
approved -
- Rated Voltage
- 1000V
Application
-
1000GH
Details- Series
- Cylindrical fast acting fuses
- Rated
Current - 16~630A
- Cylinder size
(Estimated) - φ17×66~
- Installation
method - Screwed
- Standard
approved -
- Rated Voltage
- 1000V
Application
-
1500GH
Details- Series
- Cylindrical fast acting fuses
- Rated
Current - 16~720A
- Cylinder size
(Estimated) - φ20×107~
- Installation
method - Screwed
- Standard
approved -
- Rated Voltage
- 1500V
Application
-
500KFF/500KFH/500KFK
Details- Series
- Application specific fuses
- Rated
Current - 50A
- Cylinder size
(Estimated) - φ10×38
- Installation
method - Clipped /
Screwed /
Board soldered - Standard
approved - Rated Voltage
- 500V
Application